<?xml version="1.0" encoding="utf-8"?>
<feed xmlns="http://www.w3.org/2005/Atom" xmlns:media="http://search.yahoo.com/mrss/">
    <title>Zhejiang Vabo Transformer Co.,Ltd</title>
    <link href="https://vaboelectric.com/feed.xml" rel="self" />
    <link href="https://vaboelectric.com" />
    <updated>2026-10-21T16:52:55+08:00</updated>
    <author>
        <name>Vabo</name>
    </author>
    <id>https://vaboelectric.com</id>

    <entry>
        <title>How to Correctly Select Current Transformers and Voltage Transformers for Power Transmission and Distribution Projects</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/reliable-stainless-steel-commercial-peelers-for-busy-restaurant-kitchens.html"/>
        <id>https://vaboelectric.com/reliable-stainless-steel-commercial-peelers-for-busy-restaurant-kitchens.html</id>
        <media:content url="https://vaboelectric.com/media/posts/22/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" medium="image" />
            <category term="Blogs"/>

        <updated>1970-01-01T08:00:02+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/22/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" alt="" />
                    A Professional Selection Guide for Electrical Engineers, Switchgear Manufacturers, and Power Transmission &amp; Distribution Equipment Buyers In modern power transmission and distribution systems, current transformers (CTs) and voltage transformers (VTs/PTs) are essential devices for electrical measurement, energy metering, and relay protection. For power engineering contractors,&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/22/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" class="type:primaryImage" alt="" /></p>
                <p class="codex-docx-preview_5">A Professional Selection Guide for Electrical Engineers, Switchgear Manufacturers, and Power Transmission &amp; Distribution Equipment Buyers</p>
<p class="codex-docx-preview_5">In modern power transmission and distribution systems, <a href="https://vaboelectric.com/tags/potato-peeling-machines2/" target="_blank" rel="noopener noreferrer">current transformers</a> (CTs) and voltage transformers (VTs/PTs) are essential devices for electrical measurement, energy metering, and relay protection.</p>
<p class="codex-docx-preview_5">For power engineering contractors, switchgear manufacturers, and industrial project buyers, selecting an instrument transformer involves more than just rated voltage or current ratio. Accuracy class, rated burden, insulation level, installation environment, and applicable international technical standards must also be considered.</p>
<p class="codex-docx-preview_5">The key to selecting an instrument transformer is to match its electrical performance, measurement accuracy, and environmental adaptability to the actual project requirements.</p>
<p class="codex-docx-preview_5">This article draws on actual products from Zhejiang VABO Transformer Co., Ltd. (VABO) to explain the main differences between current transformers and voltage transformers, six key selection parameters, and the application of 11 kV and 24 kV instrument transformers in power transmission and distribution systems, providing practical technical guidance for overseas buyers.</p>
<h3><span style="font-size: 18pt;">1. What Is the Difference Between a Current Transformer and a Voltage Transformer?</span></h3>
<p class="codex-docx-preview_5">Current transformers and voltage transformers are both instrument transformers, but they perform different functions in a power system.</p>
<p class="codex-docx-preview_5">1) Current Transformer (CT): Mainly converts primary current proportionally into a standard secondary current, typically 1 A or 5 A, for measuring instruments, energy metering devices, and relay protection equipment.</p>
<p class="codex-docx-preview_5">2) Voltage Transformer (VT/PT): Mainly converts high primary voltage proportionally into a lower standard secondary voltage, providing voltage signals for voltage measurement, energy metering, and relay protection equipment.</p>
<table style="border-collapse: collapse; width: 100.046%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 33.2874%;">Comparison Item</td>
<td class="align-center" style="width: 33.2874%;">Current Transformer (CT)</td>
<td class="align-center" style="width: 33.2874%;">Voltage Transformer (VT/PT)</td>
</tr>
<tr>
<td class="align-center" style="width: 33.2874%;">Main Function</td>
<td class="align-center" style="width: 33.2874%;">Current measurement</td>
<td class="align-center" style="width: 33.2874%;">Voltage measurement</td>
</tr>
<tr>
<td class="align-center" style="width: 33.2874%;">Secondary Output</td>
<td class="align-center" style="width: 33.2874%;">Typically 1 A or 5 A</td>
<td class="align-center" style="width: 33.2874%;">Typically 100 V, 110 V, or other specified voltages</td>
</tr>
<tr>
<td class="align-center" style="width: 33.2874%;">Main Applications</td>
<td class="align-center" style="width: 33.2874%;">Energy metering, current monitoring, relay protection</td>
<td class="align-center" style="width: 33.2874%;">Voltage monitoring, energy metering, relay protection</td>
</tr>
<tr>
<td class="align-center" style="width: 33.2874%;">Key Parameters</td>
<td class="align-center" style="width: 33.2874%;">Current ratio, accuracy class, rated burden, short-time thermal current, and dynamic current withstand capability</td>
<td class="align-center" style="width: 33.2874%;">Voltage ratio, accuracy class, rated burden, insulation level</td>
</tr>
<tr>
<td class="align-center" style="width: 33.2874%;">Common Installation Locations</td>
<td class="align-center" style="width: 33.2874%;">Distribution panels, switchgear, substations</td>
<td class="align-center" style="width: 33.2874%;">
<p>Switchgear, substations, voltage monitoring systems</p>
</td>
</tr>
</tbody>
</table>
<p class="codex-docx-preview_5">Both types of instrument transformers provide the electrical signals required by measurement, metering, and protection equipment in power transmission and distribution systems.</p>
<p class="codex-docx-preview_5">Safety Note: For a conventional current transformer, the secondary circuit must not be left open while the primary side is energized. The secondary circuit of a voltage transformer should be provided with short-circuit protection in accordance with the relevant technical requirements.</p>
<p class="codex-docx-preview_3"><span style="font-size: 18pt;"><strong>2. Six Key Technical Parameters to Check Before Selecting an Instrument Transformer</strong></span></p>
<p class="codex-docx-preview_4"><strong>2.1 Rated Voltage and Insulation Level</strong></p>
<p class="codex-docx-preview_5">The first step in instrument transformer selection is to confirm the rated voltage of the power system.</p>
<p class="codex-docx-preview_5">Common medium-voltage distribution systems include:</p>
<ul>
<li class="codex-docx-preview_5">11 kV distribution systems</li>
<li class="codex-docx-preview_5">22 kV distribution systems</li>
<li class="codex-docx-preview_5">33 kV distribution systems</li>
</ul>
<p class="codex-docx-preview_5">It is important to note that system nominal voltage, equipment rated voltage, and rated insulation level are not exactly the same concept.</p>
<p>For example, an instrument transformer used in an 11 kV system must not only meet the voltage-level requirement, but also comply with the corresponding power-frequency withstand voltage and lightning impulse withstand voltage requirements.</p>
<p class="codex-docx-preview_5">Procurement Tip: Before ordering, confirm the rated voltage, insulation level, and project insulation coordination requirements. Do not select a product based only on the voltage number.</p>
<p class="codex-docx-preview_4"><strong>2.2 Current Ratio or Voltage Ratio</strong></p>
<p class="codex-docx-preview_5">The current ratio is the ratio between the rated primary current and rated secondary current of a current transformer.</p>
<p class="codex-docx-preview_5">For example, for a 600/5 A current transformer:</p>
<ul>
<li class="codex-docx-preview_5 align-left">Rated primary current: 600 A</li>
<li class="align-left">Rated secondary current: 5 A</li>
<li class="codex-docx-preview_5 align-left">Nominal ratio: 120:1</li>
</ul>
<p class="codex-docx-preview_5">For a voltage transformer, the ratio refers to the relationship between the rated primary voltage and rated secondary voltage.</p>
<p class="codex-docx-preview_5">For example, for a 22000/110 V voltage transformer:</p>
<ul>
<li class="codex-docx-preview_5 align-left">Rated primary voltage: 22000 V</li>
<li class="codex-docx-preview_5 align-left">Rated secondary voltage: 110 V</li>
<li class="codex-docx-preview_5 align-left">Nominal ratio: 200:1</li>
</ul>
<p class="codex-docx-preview_5">The selected ratio must match the actual power system and the connected measurement, metering, or protection equipment.</p>
<p class="codex-docx-preview_4"><strong>2.3 Accuracy Class</strong></p>
<p class="codex-docx-preview_5">Accuracy class is an important technical indicator of an instrument transformer's measurement performance, especially in energy metering and relay protection applications.</p>
<p class="codex-docx-preview_5">Common metering accuracy classes include:</p>
<ul>
<li class="codex-docx-preview_5 align-left">Class 0.2S</li>
<li class="codex-docx-preview_5 align-left">Class 0.5S</li>
<li class="codex-docx-preview_5 align-left">Class 0.5</li>
</ul>
<p class="codex-docx-preview_5">Different types of instrument transformers have different accuracy classifications and technical requirements.</p>
<p class="codex-docx-preview_5">For relay protection applications, protection accuracy class and related performance indicators must also be considered.</p>
<p class="codex-docx-preview_5">Procurement Tip: Clearly identify whether each secondary winding is intended for measurement, metering, or relay protection, and confirm the required accuracy class for each winding.</p>
<p class="codex-docx-preview_4"><strong>2.4 Rated Burden (VA)</strong></p>
<p class="codex-docx-preview_5">Rated burden refers to the rated output load under which the secondary winding of an instrument transformer can meet the specified performance requirements. For example, some instrument transformers may provide 10 VA, 15 VA, or other rated burden configurations depending on the model. In actual selection, the following must be considered together:</p>
<ul>
<li class="codex-docx-preview_5">Measuring instrument load</li>
<li class="codex-docx-preview_5">Energy metering equipment load</li>
<li class="codex-docx-preview_5">Secondary connection lead burden</li>
<li class="codex-docx-preview_5">Relay protection device requirements</li>
</ul>
<p class="codex-docx-preview_5">If the secondary-circuit burden is not calculated correctly, measurement accuracy or protection performance may be affected.</p>
<p class="codex-docx-preview_4"><strong>2.5 Rated Short-Time Thermal Current and Rated Dynamic Current</strong></p>
<p class="codex-docx-preview_5">For current transformers used in power transmission and distribution systems, fault-current withstand capability is also a very important parameter.</p>
<p class="codex-docx-preview_5">Rated short-time thermal current (Ith): The current that a current transformer can withstand for a specified short period without unacceptable damage caused by thermal effects.</p>
<p class="codex-docx-preview_5">Rated dynamic current (Idyn): The peak current and corresponding electrodynamic effects that a current transformer can withstand under specified conditions.</p>
<p class="codex-docx-preview_5">During procurement, confirm that these two parameters meet project requirements based on the possible system short-circuit current and the protection-system design requirements.</p>
<p class="codex-docx-preview_4"><strong>2.6 Installation and Service Environment</strong></p>
<p class="codex-docx-preview_5">Depending on product design, instrument transformers may be installed indoors or outdoors.</p>
<p class="codex-docx-preview_5">Before selection, consider:</p>
<ul>
<li class="codex-docx-preview_5">Ambient temperature</li>
<li class="codex-docx-preview_5">Relative humidity</li>
<li class="codex-docx-preview_5">Installation altitude</li>
<li class="codex-docx-preview_5">Pollution level</li>
<li class="codex-docx-preview_5">Effects of moisture and rain</li>
<li class="codex-docx-preview_5">Equipment installation dimensions</li>
</ul>
<p class="codex-docx-preview_5">For power projects in Southeast Asia, environmental adaptability is especially important. Indoor epoxy-resin cast instrument transformers and outdoor oil-immersed instrument transformers may differ significantly in insulation structure, service conditions, and maintenance requirements.</p>
<p class="codex-docx-preview_5">Procurement Tip: Refer to the manufacturer's technical documentation to confirm the service environment for the specific model. Do not assume that all instrument transformers are suitable for high-humidity or outdoor environments.</p>
<p class="codex-docx-preview_3"><strong><span style="font-size: 18pt;">3. How to Select a Current Transformer for 11 kV Switchgear</span></strong></p>
<p class="codex-docx-preview_5">Medium-voltage switchgear is widely used in industrial plants, substations, and commercial building distribution systems.</p>
<p class="codex-docx-preview_5">When selecting a current transformer for 11 kV switchgear, buyers should focus on:</p>
<ul>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Rated voltage and insulation level.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Primary-to-secondary current ratio.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Metering accuracy class and protection accuracy class.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Rated secondary burden.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Short-circuit current withstand capability.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-1-0">Overall dimensions and mounting method.</li>
</ul>
<figure class="post__image align-center"><img loading="lazy"  src="https://vaboelectric.com/media/posts/22/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="348" height="433" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/22/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/22/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/22/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="codex-docx-preview_5">The VABO LZZBJ9-11 is an indoor current transformer suitable for corresponding 11 kV power systems. It is mainly used for:</p>
<ul>
<li class="codex-docx-preview_5">Current measurement</li>
<li class="codex-docx-preview_5">Energy metering</li>
<li class="codex-docx-preview_5">Relay protection</li>
<li class="codex-docx-preview_5">Indoor medium-voltage distribution equipment</li>
</ul>
<p class="codex-docx-preview_5">According to VABO's current product manual, the main technical parameters of this series are as follows:</p>
<table style="border-collapse: collapse; width: 100.015%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 49.9926%;">Technical Item</td>
<td class="align-center" style="width: 49.9926%;">Product Parameter</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Model</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p class="align-center">LZZBJ9-11</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Installation</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>Indoor</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Application Voltage Class</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>11 kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Rated Secondary Current</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>5 A or 1 A</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Insulation Level Stated in Manual</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>12/42/75 kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Accuracy-Class Configuration Example</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>0.2S, 0.5, and protection-class combinations</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 49.9926%;">
<p>Reference Standard</p>
</td>
<td class="align-center" style="width: 49.9926%;">
<p>IEC 61869-2</p>
</td>
</tr>
</tbody>
</table>
<p>The specific accuracy-class combination and current ratings should be confirmed against the latest product documentation. Switchgear manufacturers should also pay close attention to the transformer's installation dimensions, busbar arrangement, secondary terminal positions, and protection performance requirements. If you are looking for a current transformer for 11 kV switchgear, you can provide VABO with your project technical parameters and the technical team can help confirm the appropriate model.</p>
<p class="codex-docx-preview_3"><strong><span style="font-size: 18pt;">4. How to Select a Current Transformer for a 24 kV Power Transmission and Distribution System</span></strong></p>
<p class="codex-docx-preview_5">In some 22 kV distribution projects, 24 kV-class power equipment meeting the corresponding insulation-level requirements may be used.</p>
<p class="codex-docx-preview_5">However, actual selection must consider not only the equipment voltage class, but also the system insulation requirements, accuracy class, rated burden, and operating environment.</p>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/22/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="301" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/22/responsive/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/22/responsive/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/22/responsive/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="codex-docx-preview_5">The COL-24 is a 24 kV-class oil-immersed current transformer. When its rated service conditions are satisfied, it can be used for current measurement and energy metering in indoor or outdoor power systems.</p>
<p class="codex-docx-preview_5">Its main technical parameters include:</p>
<table style="border-collapse: collapse; width: 100.015%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 36.4529%;">Technical Item</td>
<td class="align-center" style="width: 63.5322%;">COL-24 Product Parameter</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Model</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>COL-24</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Rated Voltage</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>24 kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Rated Secondary Current</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>5 A</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Metering Accuracy Class</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>0.2S / 0.5</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Corresponding Rated Output Example</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>15 VA / 30 VA</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Insulation Type</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>Oil-immersed</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Installation Environment</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>Indoor or outdoor, subject to the specified product service conditions</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 36.4529%;">
<p>Reference Standard</p>
</td>
<td class="align-center" style="width: 63.5322%;">
<p>IEC 61869-2</p>
</td>
</tr>
</tbody>
</table>
<p class="codex-docx-preview_5">The specific primary current ratings and the corresponding short-time thermal current and dynamic current parameters should be determined according to VABO's technical documentation and project requirements.</p>
<p class="codex-docx-preview_4">What Should Be Considered When Purchasing a 24 kV Current Transformer?</p>
<p class="codex-docx-preview_5">Before purchasing, it is recommended to confirm:</p>
<ul>
<li class="codex-docx-preview_5">Rated primary current</li>
<li class="codex-docx-preview_5">Rated secondary current</li>
<li class="codex-docx-preview_5">Metering accuracy class</li>
<li class="codex-docx-preview_5">Short-circuit current withstand capability</li>
<li class="codex-docx-preview_5">Indoor or outdoor installation requirements</li>
<li class="codex-docx-preview_5">Ambient temperature, humidity, and altitude</li>
<li class="codex-docx-preview_5">Product overall dimensions and mounting dimensions</li>
</ul>
<p class="codex-docx-preview_5">For instrument transformers used outdoors, special attention should also be paid to insulation performance, environmental suitability, and maintenance requirements.</p>
<p class="codex-docx-preview_3"><strong>5. How to Select a Voltage Transformer for a 22 kV Distribution System</strong></p>
<p class="codex-docx-preview_5">Voltage transformers mainly provide suitable secondary voltage signals for measuring instruments, energy metering equipment, and relay protection systems.</p>
<p class="codex-docx-preview_5">When selecting a voltage transformer for a 22 kV distribution project, the following should be confirmed:</p>
<ul>
<li class="codex-docx-preview_5">Rated primary voltage</li>
<li class="codex-docx-preview_5">Rated secondary voltage</li>
<li class="codex-docx-preview_5">Accuracy class</li>
<li class="codex-docx-preview_5">Rated burden</li>
<li class="codex-docx-preview_5">Insulation level</li>
<li class="codex-docx-preview_5">Installation environment</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/22/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="408" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/22/responsive/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/22/responsive/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/22/responsive/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="codex-docx-preview_5">The VABO VOL-24 is an outdoor oil-immersed voltage transformer suitable for medium-voltage power systems that meet its technical requirements.</p>
<p class="codex-docx-preview_5">According to VABO's current product manual, the main parameters are as follows:</p>
<table style="border-collapse: collapse; width: 100.015%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 64.5737%;">Technical Item</td>
<td class="align-center" style="width: 35.4114%;">VOL-24 Product Parameter</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Model</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>VOL-24</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Rated Voltage Class</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>24 kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Rated Primary Voltage</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>22000 V</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Rated Secondary Voltage</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>110 V</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Accuracy-Class Configuration</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>0.5 / 1 / 3</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Rated Output Corresponding to Each Accuracy Class</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>50 / 80 / 200 VA</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Rated Insulation Level</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>24/50/125 kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Installation Environment</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>Outdoor</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.5737%;">
<p>Reference Standard</p>
</td>
<td class="align-center" style="width: 35.4114%;">
<p>IEC 61869-3</p>
</td>
</tr>
</tbody>
</table>
<p class="codex-docx-preview_5">Note: The accuracy classes and corresponding rated outputs shown in the table are different configuration options. They do not mean that the same winding can meet all accuracy classes and output requirements simultaneously.</p>
<p class="codex-docx-preview_5">When purchasing this type of voltage transformer, the power-system grounding method, metering requirements, and protection-function requirements should also be confirmed.</p>
<p class="codex-docx-preview_3"><span style="font-size: 18pt;"><strong>6. How to Choose Between Indoor and Outdoor Instrument Transformers</strong></span></p>
<p class="codex-docx-preview_5">The installation environment is one of the key factors in instrument transformer selection.</p>
<p class="codex-docx-preview_4"><strong>6.1 Indoor Instrument Transformers</strong></p>
<p class="codex-docx-preview_5">Indoor instrument transformers are commonly used in:</p>
<ul>
<li class="codex-docx-preview_5">Metal-enclosed switchgear</li>
<li class="codex-docx-preview_5">Indoor substations</li>
<li class="codex-docx-preview_5">Industrial distribution rooms</li>
<li class="codex-docx-preview_5">Low-voltage power distribution assemblies</li>
</ul>
<p class="codex-docx-preview_5">Some indoor instrument transformers use epoxy-resin cast insulation, providing compact equipment arrangement and insulation performance when operated within their specified service conditions.</p>
<p class="codex-docx-preview_4"><strong>6.2 Outdoor Instrument Transformers</strong></p>
<p class="codex-docx-preview_5">Outdoor instrument transformers are generally used in:</p>
<ul>
<li class="codex-docx-preview_5">Outdoor substations</li>
<li class="codex-docx-preview_5">Public utility distribution systems</li>
<li class="codex-docx-preview_5">Outdoor energy metering installations</li>
</ul>
<p class="codex-docx-preview_5">For outdoor installations, special attention should be paid to insulation structure, environmental humidity, pollution level, temperature, and other environmental factors.</p>
<p class="codex-docx-preview_4"><strong>6.3 Special Considerations for Power Projects in Southeast Asia</strong></p>
<p class="codex-docx-preview_5">Some power projects in countries such as Indonesia, Vietnam, Thailand, Malaysia, and the Philippines may face high temperatures, high humidity, coastal salt mist, or industrial pollution. However, actual environmental conditions vary significantly by country and region, so a single set of environmental assumptions should not replace project-specific data.</p>
<p class="codex-docx-preview_5">Buyers should focus on confirming:</p>
<ul>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Actual climate and environmental conditions at the project site.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Technical specifications of the local utility or engineering project.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Applicable IEC standards.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Pollution level and insulation requirements.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Installation altitude and temperature limits.</li>
<li class="codex-docx-preview_5 codex-docx-preview-num-2-0">Required technical documents and test records.</li>
</ul>
<p class="codex-docx-preview_5 codex-docx-preview-num-0-undefined">Correct instrument transformer selection requires not only matching the voltage level, but also satisfying the complete set of project technical requirements.</p>
<p class="codex-docx-preview_3"><strong><span style="font-size: 18pt;">7. How to Select a Reliable Instrument Transformer Manufacturer</span></strong></p>
<p class="codex-docx-preview_5">For OEM buyers, power engineering contractors, and switchgear manufacturers, selecting an instrument transformer supplier should not be based on product price alone.</p>
<p class="codex-docx-preview_5">It is recommended to evaluate the following five aspects comprehensively.</p>
<p class="codex-docx-preview_4"><strong>7.1 Is the Product Range Complete?</strong></p>
<p class="codex-docx-preview_5">First, confirm whether the manufacturer can provide the project requirements for:</p>
<ul>
<li class="codex-docx-preview_5">Voltage levels</li>
<li class="codex-docx-preview_5">Current ratios</li>
<li class="codex-docx-preview_5">Accuracy classes</li>
<li class="codex-docx-preview_5">Installation types</li>
<li class="codex-docx-preview_5">Special structures and configurations</li>
</ul>
<p class="codex-docx-preview_5">A supplier with multiple product series can help customers source instrument transformers for different application scenarios.</p>
<p class="codex-docx-preview_4"><strong>7.2 Is the Technical Documentation Complete?</strong></p>
<p class="codex-docx-preview_5">Before purchasing, it is recommended to request the following from the manufacturer:</p>
<ul>
<li class="codex-docx-preview_5">Product technical manuals</li>
<li class="codex-docx-preview_5">Outline and installation dimension drawings</li>
<li class="codex-docx-preview_5">Wiring diagrams</li>
<li class="codex-docx-preview_5">Rated electrical parameters</li>
<li class="codex-docx-preview_5">Applicable test documentation</li>
</ul>
<p class="codex-docx-preview_5">Complete and clear technical documentation helps reduce errors during product selection and installation.</p>
<p class="codex-docx-preview_4"><strong>7.3 Does the Manufacturer Have Appropriate Quality Inspection Capabilities?</strong></p>
<p class="codex-docx-preview_5">Buyers should understand the manufacturer's inspection and testing process and, depending on the specific product requirements, confirm the following inspection items:</p>
<ul>
<li class="codex-docx-preview_5">Ratio test</li>
<li class="codex-docx-preview_5">Accuracy performance test</li>
<li class="codex-docx-preview_5">Insulation performance test</li>
<li class="codex-docx-preview_5">Terminal and marking inspection</li>
<li class="codex-docx-preview_5">Product traceability and identification management</li>
</ul>
<p class="codex-docx-preview_5">The specific scope of inspection and required documents should be determined according to the product type and technical requirements of the order.</p>
<p class="codex-docx-preview_4"><strong>7.4 Does the Manufacturer Support OEM/ODM Customization?</strong></p>
<p class="codex-docx-preview_5">For switchgear manufacturers and electrical equipment suppliers, different projects may have different product requirements, including:</p>
<ul>
<li class="codex-docx-preview_5">Current ratio or voltage ratio</li>
<li class="codex-docx-preview_5">Winding combinations</li>
<li class="codex-docx-preview_5">Accuracy class and rated burden</li>
<li class="codex-docx-preview_5">Installation dimensions</li>
<li class="codex-docx-preview_5">Terminal structure</li>
</ul>
<p class="codex-docx-preview_5">Specific customization requirements should be confirmed after a feasibility review by the manufacturer's technical team.</p>
<p class="codex-docx-preview_4"><strong>7.5 Does the Manufacturer Provide Technical Support and Delivery Services?</strong></p>
<p class="codex-docx-preview_5">Buyers should also understand the manufacturer's:</p>
<ul>
<li class="codex-docx-preview_5">Technical communication process</li>
<li class="codex-docx-preview_5">Product production lead time</li>
<li class="codex-docx-preview_5">Ability to provide quality documentation</li>
<li class="codex-docx-preview_5">After-sales service arrangements</li>
</ul>
<p class="codex-docx-preview_5">These factors are particularly important for overseas power infrastructure and industrial projects.</p>
<p class="codex-docx-preview_3"><span style="font-size: 18pt;"><strong>8. About VABO: An Instrument Transformer Manufacturer from China</strong></span></p>
<p class="codex-docx-preview_5">Zhejiang VABO Transformer Co., Ltd. is located in Yueqing, Zhejiang Province, China, and specializes in the research, development, and manufacturing of instrument transformers and related power transmission and distribution products.</p>
<p class="codex-docx-preview_5">VABO's main products include:</p>
<ul>
<li class="codex-docx-preview_5">Low-voltage current transformers</li>
<li class="codex-docx-preview_5">Medium-voltage current transformers</li>
<li class="codex-docx-preview_5">Voltage transformers</li>
<li class="codex-docx-preview_5">Zero-sequence current transformers</li>
<li class="codex-docx-preview_5">Combined instrument transformers</li>
<li class="codex-docx-preview_5">Energy metering equipment</li>
<li class="codex-docx-preview_5">Related power transmission and distribution products</li>
</ul>
<p class="codex-docx-preview_5">The company also provides OEM/ODM customization, technical consulting, and after-sales service.</p>
<p class="codex-docx-preview_5">VABO instrument transformers cover different voltage levels, installation environments, and measurement requirements. Based on the project technical information provided by customers, VABO can assist with product selection and configuration confirmation.</p>
<p class="codex-docx-preview_5">For overseas customers, VABO can conduct technical evaluations based on specific project specifications and communicate suitable product solutions.</p>
<p class="codex-docx-preview_3"><strong><span style="font-size: 18pt;">9. Technical Parameter Checklist for Instrument Transformer Procurement</span></strong></p>
<p class="codex-docx-preview_5">Before requesting a quotation from a manufacturer, buyers are advised to prepare the following information.</p>
<table style="border-collapse: collapse; width: 100.015%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 35.709%;">Procurement Information</td>
<td class="align-center" style="width: 64.2761%;">Example Entry</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Project Country</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>Indonesia / Vietnam / Malaysia</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Application</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>11 kV switchgear / 22 kV distribution system</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Product Type</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>CT / VT / combined instrument transformer</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Rated Voltage</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>11 kV / 22 kV / 33 kV system</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Current or Voltage Ratio</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>600/5 A, 22000/110 V</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Accuracy Class</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>0.2S / 0.5 / required protection accuracy class</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Rated Burden</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>10 VA / 15 VA / other specified value</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Installation Environment</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>Indoor / Outdoor</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Purchase Quantity</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>To be determined according to the actual project</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Technical Standard</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>IEC standards / local utility project specifications</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 35.709%;">
<p>Delivery Requirement</p>
</td>
<td class="align-center" style="width: 64.2761%;">
<p>Delivery time required by the project</p>
</td>
</tr>
</tbody>
</table>
<p class="codex-docx-preview_5">Providing complete technical information helps the manufacturer confirm product suitability more quickly and improves the efficiency of technical communication and quotation.</p>
<p class="codex-docx-preview_3"><span style="font-size: 18pt;"><strong>10. Frequently Asked Questions About Instrument Transformers (FAQ)</strong></span></p>
<p class="codex-docx-preview_4"><strong>Q1: What is the difference between a current transformer and a voltage transformer?</strong></p>
<p class="codex-docx-preview_5">A current transformer converts primary current into a standard secondary current according to a specified ratio, while a voltage transformer converts primary voltage into a lower secondary voltage. Both are used in electrical measurement, energy metering, and relay protection systems.</p>
<p class="codex-docx-preview_4"><strong>Q2: What current transformer should be selected for 11 kV switchgear?</strong></p>
<p class="codex-docx-preview_5">A current transformer used in 11 kV switchgear must meet the system requirements for voltage level, insulation level, current ratio, accuracy class, rated burden, short-circuit withstand capability, and installation dimensions.</p>
<p class="codex-docx-preview_5">The VABO LZZBJ9-11 series is a current transformer suitable for corresponding 11 kV indoor power systems.</p>
<p class="codex-docx-preview_4"><strong>Q3: Can a 24 kV current transformer be used in a 22 kV distribution system?</strong></p>
<p class="codex-docx-preview_5">When the relevant technical conditions are satisfied, a 24 kV-class current transformer can be used in a suitable 22 kV distribution system.</p>
<p class="codex-docx-preview_5">However, its insulation level, electrical parameters, installation environment, and other performance characteristics must comply with the project technical requirements.</p>
<p class="codex-docx-preview_4"><strong>Q4: What accuracy class should be selected for energy metering?</strong></p>
<p class="codex-docx-preview_5">The accuracy class should be determined according to the metering application, technical standards, and actual operating conditions.</p>
<p class="codex-docx-preview_5">Classes 0.2S, 0.5S, and 0.5 are suitable for different metering requirements. The final selection should be based on the project specification and product technical conditions.</p>
<p class="codex-docx-preview_4"><strong>Q5: Can instrument transformers be used in hot and humid tropical regions?</strong></p>
<p class="codex-docx-preview_5">Yes, provided that the design and rated service conditions of the specific product meet the actual environmental requirements.</p>
<p class="codex-docx-preview_5">During procurement, confirm that temperature, humidity, pollution level, altitude, and installation conditions comply with the product manual.</p>
<p class="codex-docx-preview_4"><strong>Q6: Does VABO provide customized instrument transformers?</strong></p>
<p class="codex-docx-preview_5">VABO provides OEM/ODM customization services.</p>
<p class="codex-docx-preview_5">Customers can submit the required electrical parameters and mechanical structure requirements. VABO's technical team will evaluate them and confirm the available product configurations.</p>
<p class="codex-docx-preview_3"><span style="font-size: 18pt;"><strong>11. Contact VABO for Instrument Transformer Technical Support and Quotations</strong></span></p>
<p class="codex-docx-preview_5">Are you looking for current transformers, voltage transformers, or combined instrument transformers for a new power engineering project?</p>
<p class="codex-docx-preview_5">Zhejiang VABO Transformer Co., Ltd. (VABO) can provide instrument transformer product-selection support for switchgear manufacturing, substations, industrial power transmission and distribution, and related projects.</p>
<p class="codex-docx-preview_5">To help us understand your project requirements, we recommend providing:</p>
<ul>
<li class="codex-docx-preview_5">Project country and application scenario</li>
<li class="codex-docx-preview_5">Rated voltage</li>
<li class="codex-docx-preview_5">Current ratio or voltage ratio</li>
<li class="codex-docx-preview_5">Accuracy class and rated burden</li>
<li class="codex-docx-preview_5">Installation environment</li>
<li class="codex-docx-preview_5">Purchase quantity</li>
<li class="codex-docx-preview_5">Relevant technical drawings or specification requirements</li>
</ul>
<p class="codex-docx-preview_5">Contact VABO for technical consultation and procurement quotations for instrument transformer products.</p>
<p class="codex-docx-preview_5">Technical Note: Final product selection and configuration should be determined according to the latest confirmed product technical documentation and applicable project standards.</p>
            ]]>
        </content>
    </entry>
    <entry>
        <title>CT Accuracy Class 0.2S vs 0.5S: Which One Should You Choose?</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/durable-high-volume-industrial-peelers-perfect-for-commercial-food-plants.html"/>
        <id>https://vaboelectric.com/durable-high-volume-industrial-peelers-perfect-for-commercial-food-plants.html</id>
        <media:content url="https://vaboelectric.com/media/posts/21/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Blogs"/>

        <updated>1970-01-01T08:00:02+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/21/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    Accuracy class is one of the most important parameters when selecting a current transformer (CT) for energy metering. Two common classes are 0.2S and 0.5S. Understanding their differences helps engineers and buyers select suitable equipment for power distribution projects. What Does CT Accuracy Class Mean?&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/21/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>Accuracy class is one of the most important parameters when selecting a current transformer (CT) for energy metering.</p>
<p>Two common classes are 0.2S and 0.5S. Understanding their differences helps engineers and buyers select suitable equipment for power distribution projects.</p>
<p><strong><span style="font-size: 18pt;">What Does CT Accuracy Class Mean?</span></strong></p>
<p>Accuracy class defines the permitted current and phase errors under specified operating and burden conditions.</p>
<p>A lower accuracy class number generally indicates tighter measurement error limits.</p>
<p>For metering CTs, the letter “S” identifies a class with defined accuracy requirements extending into lower current ranges.</p>
<p><strong><span style="font-size: 18pt;">0.2S vs 0.5S</span></strong></p>
<p>A 0.2S CT provides tighter accuracy requirements than a 0.5S CT under the conditions specified by the applicable standard.</p>
<p>Both classes have specified error limits at different percentages of rated current, rather than one constant error percentage across all operating conditions.</p>
<p><strong><span style="font-size: 18pt;">Which Accuracy Class Should Buyers Select?</span></strong></p>
<p>The correct choice depends on:</p>
<ul>
<li>Revenue metering requirements</li>
<li>Expected operating current</li>
<li>Connected secondary burden</li>
<li>Applicable utility standards</li>
<li>Project technical specifications</li>
</ul>
<p>For applications requiring stricter metering performance, 0.2S may be specified. For other metering applications, 0.5S may be acceptable.</p>
<p><span style="font-size: 18pt;"><strong>VABO Current Transformer Solutions</strong></span></p>
<p>Established in 1985, Zhejiang VABO Transformer Co., Ltd. manufactures instrument transformers for electrical distribution applications.</p>
<p>VABO offers current transformer models with different accuracy configurations, including the LZZBJ9-11 and COL-24 series.</p>
<p>Available accuracy classes and burden ratings must be confirmed for each model.</p>
<p><strong>Need a metering CT for your project? Contact VABO with your current ratio, accuracy class, rated burden, and quantity for technical review and quotation.</strong></p>
<p> </p>
<p> </p>
<p> </p>
<p> </p>
            ]]>
        </content>
    </entry>
    <entry>
        <title>How to Choose an 11kV Current Transformer for Switchgear</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/professional-grade-industrial-peelers-designed-for-root-vegetables-and-potatoes.html"/>
        <id>https://vaboelectric.com/professional-grade-industrial-peelers-designed-for-root-vegetables-and-potatoes.html</id>
        <media:content url="https://vaboelectric.com/media/posts/20/Tu-17_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Blogs"/>

        <updated>1970-01-01T08:00:02+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/20/Tu-17_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    Selecting the correct 11kV current transformer is essential for accurate metering, electrical monitoring, and relay protection. For switchgear manufacturers and electrical contractors, voltage rating alone is not enough to determine the right CT. Six Parameters to Check Before purchasing an 11kV current transformer, verify: For&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/20/Tu-17_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>Selecting the correct 11kV current transformer is essential for accurate metering, electrical monitoring, and relay protection.</p>
<p>For switchgear manufacturers and electrical contractors, voltage rating alone is not enough to determine the right CT.</p>
<p><span style="font-size: 18pt;"><strong>Six Parameters to Check</strong></span></p>
<p>Before purchasing an 11kV current transformer, verify:</p>
<ul>
<li>Rated system voltage and insulation level</li>
<li>Primary and secondary current ratio</li>
<li>Metering and protection accuracy classes</li>
<li>Rated secondary burden (VA)</li>
<li>Short-time thermal and dynamic current ratings</li>
<li>Mounting dimensions and terminal arrangements</li>
</ul>
<p> </p>
<p>For example, a 600/5A CT has a nominal current transformation ratio of 120:1.</p>
<p>However, the required primary current should be selected according to the actual circuit design.</p>
<p><span style="font-size: 18pt;"><strong>VABO LZZBJ9-11 Current Transformer</strong></span></p>
<p>The VABO LZZBJ9-11 is designed for suitable indoor 11kV power distribution applications.</p>
<p>According to VABO product documentation, the series offers:</p>
<ul>
<li>Rated secondary current: 5A or 1A</li>
<li>Documented insulation level: 12/42/75kV</li>
<li>Metering and protection accuracy configurations</li>
<li>Indoor installation</li>
</ul>
<p>The final configuration must be verified against the approved product datasheet.</p>
<p><strong><span style="font-size: 18pt;">Why Installation Dimensions Matter</span></strong></p>
<p>Switchgear manufacturers should verify the CT's mounting dimensions, conductor arrangement, and secondary terminal accessibility before confirming an order.</p>
<p>A correct electrical rating does not guarantee mechanical compatibility.</p>
<p><strong><span style="font-size: 18pt;">Work With VABO</span></strong></p>
<p>Established in 1985, Zhejiang VABO Transformer Co., Ltd. supplies instrument transformers for power distribution applications.</p>
<p><strong>Send VABO your switchgear drawings, current ratio, accuracy class, and quantity to request technical selection support and a quotation.</strong></p>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/20/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="348" height="433" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/20/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/20/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/20/responsive/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p> </p>
            ]]>
        </content>
    </entry>
    <entry>
        <title>24kV Current Transformer: Selection Guide for Power Distribution</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/robust-abrasive-industrial-peelers-with-minimal-waste-and-maximum-efficiency.html"/>
        <id>https://vaboelectric.com/robust-abrasive-industrial-peelers-with-minimal-waste-and-maximum-efficiency.html</id>
        <media:content url="https://vaboelectric.com/media/posts/19/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Blogs"/>

        <updated>1970-01-01T08:00:02+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/19/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    A 24kV current transformer (CT) provides secondary current signals for electrical measurement and metering in suitable medium-voltage systems. For electrical utilities, contractors, and equipment manufacturers, selecting the correct CT requires consideration of accuracy, insulation, current ratings, and environmental conditions. What Is a 24kV Current Transformer&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/19/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>A 24kV current transformer (CT) provides secondary current signals for electrical measurement and metering in suitable medium-voltage systems.</p>
<p>For electrical utilities, contractors, and equipment manufacturers, selecting the correct CT requires consideration of accuracy, insulation, current ratings, and environmental conditions.</p>
<p><span style="font-size: 18pt;"><strong>What Is a 24kV Current Transformer Used For?</strong></span></p>
<p>A 24kV-class CT may be specified for suitable medium-voltage distribution installations, including certain 22kV systems, subject to applicable standards and project insulation requirements.</p>
<p>Common applications include:</p>
<ul>
<li>1、Electrical substations</li>
<li>2、Power distribution networks</li>
<li>3、Outdoor metering installations</li>
<li>4、Industrial electrical systems</li>
</ul>
<p><strong><span style="font-size: 18pt;">VABO COL-24 Current Transformer</span></strong></p>
<p>The COL-24 is an oil-immersed instrument transformer designed for current measurement and energy metering.</p>
<p>Documented specifications include:</p>
<table style="border-collapse: collapse; width: 100.015%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 64.9457%;">Parameter</td>
<td class="align-center" style="width: 35.0394%;">Specification</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Rated voltage</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>24kV</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Secondary current</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>5A</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Accuracy options</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>0.2S / 0.5</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Corresponding rated outputs</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>15VA / 30VA</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Insulation</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>Oil-immersed</p>
</td>
</tr>
<tr>
<td class="align-center" style="width: 64.9457%;">
<p>Standard reference</p>
</td>
<td class="align-center" style="width: 35.0394%;">
<p>IEC 61869-2</p>
</td>
</tr>
</tbody>
</table>
<p>The available primary current ratios and fault-current withstand ratings depend on the selected configuration.</p>
<p><span style="font-size: 18pt;"><strong>Important Buying Considerations</strong></span></p>
<p>Before placing an order, confirm:</p>
<ul>
<li>1、Current ratio and accuracy class</li>
<li>2、Rated burden</li>
<li>3、Short-circuit withstand requirements</li>
<li>4、Indoor or outdoor installation</li>
<li>5、Ambient temperature, humidity, and altitude</li>
<li>6、Applicable utility standards</li>
</ul>
<p> </p>
<p>Oil-immersed insulation does not automatically make a CT suitable for every outdoor environment. The product's rated service conditions must be checked.</p>
<p> </p>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JLSZ□-35 35kV Outdoor Combined Metering Unit</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/commercial-potato-washing-equipment-117-3.html"/>
        <id>https://vaboelectric.com/commercial-potato-washing-equipment-117-3.html</id>
        <media:content url="https://vaboelectric.com/media/posts/93/Tu-2_Di-1Ye_JLSZ-35-Product-Manual-English-Edition.jpg" medium="image" />
            <category term="Products"/>
            <category term="Combined Instrument Transformers"/>

        <updated>2026-10-16T10:14:47+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/93/Tu-2_Di-1Ye_JLSZ-35-Product-Manual-English-Edition.jpg" alt="" />
                    The JLSZ□-35 is a three-phase outdoor combined metering unit integrating current and voltage transformers for accurate active and reactive energy metering in 35kV power systems. Technical Details Technical Parameters Parameter Value Model JLSZ□-35 Rated Primary Voltage 35 kV Rated Frequency 50 Hz Rated Voltage Ratio&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/93/Tu-2_Di-1Ye_JLSZ-35-Product-Manual-English-Edition.jpg" class="type:primaryImage" alt="" /></p>
                <p>The JLSZ□-35 is a three-phase outdoor combined metering unit integrating current and voltage transformers for accurate active and reactive energy metering in 35kV power systems.</p>
<p data-start="2489" data-end="2510"><strong data-start="2489" data-end="2510">Technical Details</strong></p>
<ul>
<li>35kV System </li>
<li>CT &amp; VT Integrated </li>
<li>0.2S / 0.5S Accuracy </li>
<li>Outdoor Dry-Cast </li>
<li>Wide Current Range </li>
<li>Flexible Metering</li>
</ul>
<p> </p>
<h2><span style="font-size: 18pt; color: #000000;">Technical Parameters</span></h2>
<div>
<div>
<div>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Model</strong></td>
<td>JLSZ□-35</td>
</tr>
<tr>
<td><strong>Rated Primary Voltage</strong></td>
<td>35 kV</td>
</tr>
<tr>
<td><strong>Rated Frequency</strong></td>
<td>50 Hz</td>
</tr>
<tr>
<td><strong>Rated Voltage Ratio</strong></td>
<td>35000 / 100 V</td>
</tr>
<tr>
<td><strong>Rated Primary Current</strong></td>
<td>2.5–100 A, stepped</td>
</tr>
<tr>
<td><strong>Rated Secondary Current</strong></td>
<td>5 A or 1 A</td>
</tr>
<tr>
<td><strong>Accuracy Class</strong></td>
<td>0.2 / 0.5 / 0.2S / 0.5S</td>
</tr>
<tr>
<td><strong>Dual-Ratio CT Taps</strong></td>
<td>S1-S2 low ratio / S1-S3 high ratio</td>
</tr>
<tr>
<td><strong>Installation</strong></td>
<td>Outdoor</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JLSZ□-20 20kV Outdoor Combined Metering Unit</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/commercial-potato-washing-equipment-117-2.html"/>
        <id>https://vaboelectric.com/commercial-potato-washing-equipment-117-2.html</id>
        <media:content url="https://vaboelectric.com/media/posts/92/Tu-2_Di-1Ye_JLSZ-20-Product-Manual-English-Edition.jpg" medium="image" />
            <category term="Products"/>
            <category term="Combined Instrument Transformers"/>

        <updated>2026-10-16T10:09:39+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/92/Tu-2_Di-1Ye_JLSZ-20-Product-Manual-English-Edition.jpg" alt="" />
                    The JLSZ□-20 is a three-phase outdoor combined metering unit integrating CT and VT functions for accurate active and reactive energy metering in 20kV power systems. Technical Details Technical Parameters Parameter Value Model JLSZ□-20 Rated Primary Voltage 20 kV Rated Frequency 50 Hz Rated Voltage Ratio&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/92/Tu-2_Di-1Ye_JLSZ-20-Product-Manual-English-Edition.jpg" class="type:primaryImage" alt="" /></p>
                <p>The JLSZ□-20 is a three-phase outdoor combined metering unit integrating CT and VT functions for accurate active and reactive energy metering in 20kV power systems.</p>
<p data-start="2489" data-end="2510"><strong data-start="2489" data-end="2510">Technical Details</strong></p>
<ul>
<li>20kV System</li>
<li>CT &amp; VT Integrated </li>
<li>0.2S / 0.5S Accuracy </li>
<li>Dry-Cast &amp; Sealed </li>
<li>Outdoor Application </li>
<li>Dual Wiring Options</li>
</ul>
<p> </p>
<h2><span style="font-size: 18pt; color: #000000;">Technical Parameters</span></h2>
<div>
<div>
<div>
<table>
<thead>
<tr>
<th>Parameter</th>
<th>Value</th>
</tr>
</thead>
<tbody>
<tr>
<td><strong>Model</strong></td>
<td>JLSZ□-20</td>
</tr>
<tr>
<td><strong>Rated Primary Voltage</strong></td>
<td>20 kV</td>
</tr>
<tr>
<td><strong>Rated Frequency</strong></td>
<td>50 Hz</td>
</tr>
<tr>
<td><strong>Rated Voltage Ratio</strong></td>
<td>20000 / 100 V</td>
</tr>
<tr>
<td><strong>Rated Primary Current</strong></td>
<td>2.5–100 A, stepped</td>
</tr>
<tr>
<td><strong>Rated Secondary Current</strong></td>
<td>5 A or 1 A</td>
</tr>
<tr>
<td><strong>Accuracy Class</strong></td>
<td>0.2 / 0.5 / 0.2S / 0.5S</td>
</tr>
<tr>
<td><strong>Dual-Ratio CT Taps</strong></td>
<td>S1-S2 low ratio / S1-S3 high ratio</td>
</tr>
<tr>
<td><strong>Installation</strong></td>
<td>Outdoor</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDZ(X)10-11 Indoor Voltage Transformer Series</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-8.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-8.html</id>
        <media:content url="https://vaboelectric.com/media/posts/89/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-15T13:10:49+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/89/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" alt="" />
                    The JDZ10-10 is a compact indoor epoxy-cast voltage transformer for electrical measurement, voltage monitoring, and relay protection in 10kV power systems. The JDZX10-10 is an indoor epoxy-cast voltage transformer with a residual voltage winding, designed for measurement and protection in 10kV systems. Technical Parameters Rated&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/89/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" class="type:primaryImage" alt="" /></p>
                <p>The <strong>JDZ10-10 </strong>is a compact indoor epoxy-cast voltage transformer for electrical measurement, voltage monitoring, and relay protection in 10kV power systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Voltage: 11 kV</li>
<li>Rated Secondary Voltage: 0.1 kV</li>
<li>Accuracy Class: 0.2 / 0.5</li>
<li>Rated Output: 15 / 30 VA</li>
<li>Maximum Output: 200 VA</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Installation: Indoor</li>
<li>Frequency: 50/60 Hz</li>
<li>Altitude: ≤1000 m</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/89/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="500" height="264" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/89/responsive/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/89/responsive/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/89/responsive/Tu-18_Di-16Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
<p>The<strong> JDZX10-10 </strong>is an indoor epoxy-cast voltage transformer with a residual voltage winding, designed for measurement and protection in 10kV systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Voltage: 10/√3 kV</li>
<li>Rated Secondary Voltage: 0.1/√3 kV</li>
<li>Residual Voltage: 0.1/3 kV</li>
<li>Measurement Accuracy: 0.2 / 0.5</li>
<li>Protection Accuracy: 6P</li>
<li>Rated Output: 15 or 30 VA</li>
<li>Residual Winding Output: 50 VA</li>
<li>Maximum Output: 200 VA</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Installation: Indoor</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/89/Tu-19_Di-16Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="500" height="272" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/89/responsive/Tu-19_Di-16Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/89/responsive/Tu-19_Di-16Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/89/responsive/Tu-19_Di-16Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDZW-11 11kV Outdoor Voltage Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-7.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-7.html</id>
        <media:content url="https://vaboelectric.com/media/posts/88/Tu-15_Di-13Ye_Dian-Ya-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-15T09:45:23+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/88/Tu-15_Di-13Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" />
                    The JDZW-11 is a compact outdoor epoxy-cast voltage transformer for energy metering, voltage monitoring, and relay protection in 11kV power systems. Technical Parameters Rated Primary Voltage: 11 kV Rated Secondary Voltage: 0.11 kV Accuracy Class: 0.2 / 0.5 Rated Output: 30 / 50 VA Maximum&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/88/Tu-15_Di-13Ye_Dian-Ya-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The JDZW-11 is a compact outdoor epoxy-cast voltage transformer for energy metering, voltage monitoring, and relay protection in 11kV power systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Voltage: 11 kV</li>
<li>Rated Secondary Voltage: 0.11 kV</li>
<li>Accuracy Class: 0.2 / 0.5</li>
<li>Rated Output: 30 / 50 VA</li>
<li>Maximum Output: 400 VA</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Installation: Outdoor</li>
<li>Frequency: 50/60 Hz</li>
<li>Altitude: ≤1000 m</li>
<li>Pollution Level: Class II</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDZ(X)9-33 Indoor Voltage Transformer Series</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-6.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-6.html</id>
        <media:content url="https://vaboelectric.com/media/posts/87/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-15T09:05:51+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/87/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" alt="" />
                    The JDZ9-35 is a fully enclosed epoxy-cast indoor voltage transformer designed for electrical measurement, voltage monitoring, and relay protection in 35kV power systems. The JDZX9-35 is a 35kV indoor epoxy-cast voltage transformer with measurement and residual voltage windings for metering, monitoring, and relay protection. Specifications&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/87/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" class="type:primaryImage" alt="" /></p>
                <p>The <strong>JDZ9-35</strong> is a fully enclosed epoxy-cast indoor voltage transformer designed for electrical measurement, voltage monitoring, and relay protection in 35kV power systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Voltage Ratio: 35 / 0.1 kV</li>
<li>Accuracy Class: 0.2 / 0.5</li>
<li>Rated Output: 60 / 120 VA</li>
<li>Maximum Output: 600 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
<li>Installation: Indoor</li>
<li>Altitude: ≤2000 m</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/87/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="530" height="252" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/87/responsive/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/87/responsive/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/87/responsive/Tu-13_Di-11Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
<p>The <strong>JDZX9-35</strong> is a 35kV indoor epoxy-cast voltage transformer with measurement and residual voltage windings for metering, monitoring, and relay protection.</p>
<p data-start="1200" data-end="1218"><strong data-start="1200" data-end="1218">Specifications</strong></p>
<ul data-start="1220" data-end="1466">
<li>Primary Voltage: 35/√3 kV</li>
<li>Secondary Voltage: 0.1/√3 kV</li>
<li>Residual Voltage: 0.1/3 kV</li>
<li>Accuracy: 0.2 / 0.5 / 6P</li>
<li>Rated Output: 30 / 50 / 100 VA</li>
<li>Maximum Output: 500 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
<li>Installation: Indoor</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/87/Tu-14_Di-11Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="572" height="321" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/87/responsive/Tu-14_Di-11Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/87/responsive/Tu-14_Di-11Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/87/responsive/Tu-14_Di-11Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDZ(X)W-33 Outdoor Voltage Transformer Series</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-5.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-5.html</id>
        <media:content url="https://vaboelectric.com/media/posts/86/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-15T09:02:08+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/86/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" alt="" />
                    The JDZW-35 is an outdoor epoxy-resin voltage transformer designed for energy metering, voltage monitoring, and relay protection in high-voltage power systems. The JDZXW-35 is an outdoor epoxy-cast voltage transformer with measurement and residual voltage windings for metering, monitoring, and protection applications. Specifications Primary Voltage: 35/√3&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/86/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-2.jpg" class="type:primaryImage" alt="" /></p>
                <p>The <strong>JDZW-35</strong> is an outdoor epoxy-resin voltage transformer designed for energy metering, voltage monitoring, and relay protection in high-voltage power systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Voltage Ratio: 35 / 0.11 kV</li>
<li>Accuracy Class: 0.2 / 0.5</li>
<li>Rated Output: 60 / 120 VA</li>
<li>Maximum Output: 600 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
<li>Installation: Outdoor</li>
<li>Frequency: 50/60 Hz</li>
<li>Altitude: ≤1000 m</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/86/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="145" height="240" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/86/responsive/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/86/responsive/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/86/responsive/Tu-7_Di-8Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
<p>The <strong>JDZXW-35</strong> is an outdoor epoxy-cast voltage transformer with measurement and residual voltage windings for metering, monitoring, and protection applications.</p>
<p data-start="1200" data-end="1218"><strong data-start="1200" data-end="1218">Specifications</strong></p>
<ul data-start="1220" data-end="1466">
<li>Primary Voltage: 35/√3 kV</li>
<li>Secondary Voltage: 0.1/√3 kV</li>
<li>Residual Voltage: 0.1/3 kV</li>
<li>Accuracy Class: 0.2 / 0.5 / 6P</li>
<li>Rated Output: 30 / 50 / 100 VA</li>
<li>Maximum Output: 500 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
</ul>
<figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/86/Tu-9_Di-8Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" width="106" height="247" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/86/responsive/Tu-9_Di-8Ye_Dian-Ya-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/86/responsive/Tu-9_Di-8Ye_Dian-Ya-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/86/responsive/Tu-9_Di-8Ye_Dian-Ya-Hu-Gan-Qi-md.jpg 768w"></figure>
            ]]>
        </content>
    </entry>
    <entry>
        <title>VOL-24 24kV Outdoor Voltage Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-4.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-4.html</id>
        <media:content url="https://vaboelectric.com/media/posts/85/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-14T15:51:02+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/85/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" />
                    The VOL-24 is a 24kV oil-immersed outdoor voltage transformer designed for electrical measurement and relay protection in 50/60Hz power systems. Specifications Rated Primary Voltage: 22,000 V Rated Secondary Voltage: 110 V System Voltage: 24 kV Accuracy Class: 0.5 / 1 / 3 Rated Output: 50&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/85/Tu-5_Di-5Ye_Dian-Ya-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The VOL-24 is a 24kV oil-immersed outdoor voltage transformer designed for electrical measurement and relay protection in 50/60Hz power systems.</p>
<p data-start="1200" data-end="1218"><strong data-start="1200" data-end="1218">Specifications</strong></p>
<ul data-start="1220" data-end="1466">
<li>Rated Primary Voltage: 22,000 V</li>
<li>Rated Secondary Voltage: 110 V</li>
<li>System Voltage: 24 kV</li>
<li>Accuracy Class: 0.5 / 1 / 3</li>
<li>Rated Output: 50 / 80 / 200 VA</li>
<li>Maximum Output: 500 VA</li>
<li>Insulation Level: 24 / 50 / 125 kV</li>
<li>Frequency: 50/60 Hz</li>
<li>Installation: Outdoor</li>
<li>Ambient Temperature: -25°C to +40°C</li>
<li>Altitude: ≤2000 m</li>
<li>Wind Speed: &lt;34 m/s</li>
<li>Standard: IEC 61869-3 / GB/T 20840.3</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDJJ2-33 33kV Outdoor Voltage Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-3.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series-3.html</id>
        <media:content url="https://vaboelectric.com/media/posts/84/Tu-3_Di-3Ye_Dian-Ya-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-10-14T15:50:59+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/84/Tu-3_Di-3Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" />
                    The JDJJ2-33 is a 33kV single-phase oil-immersed voltage transformer with an additional residual voltage winding for measurement and protection applications. Technical Parameters Rated Primary Voltage: 33/√3 kV Rated Secondary Voltage: 0.11/√3 kV Residual Winding Voltage: 0.11/3 kV Accuracy Class: 0.2 / 0.5 / 1 /&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/84/Tu-3_Di-3Ye_Dian-Ya-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The JDJJ2-33 is a 33kV single-phase oil-immersed voltage transformer with an additional residual voltage winding for measurement and protection applications.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Voltage: 33/√3 kV</li>
<li>Rated Secondary Voltage: 0.11/√3 kV</li>
<li>Residual Winding Voltage: 0.11/3 kV</li>
<li>Accuracy Class: 0.2 / 0.5 / 1 / 6P</li>
<li>Rated Output: 60 / 150 / 250 / 500 VA</li>
<li>Maximum Output: 1000 VA</li>
<li>Insulation Level: 40.5 / 95 / 200 kV</li>
<li>Installation: Outdoor</li>
<li>Frequency: 50 Hz</li>
<li>Altitude: ≤2000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LMZW-0.5(0.66) Outdoor Low-Voltage Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-12-2.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-12-2.html</id>
        <media:content url="https://vaboelectric.com/media/posts/83/Tu-68_Di-37Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:43:50+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/83/Tu-68_Di-37Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LMZW-0.5(0.66) is a fully enclosed outdoor current transformer for low-voltage power systems, designed for energy metering, current measurement, and relay protection. Technical Parameters Rated Primary Current: 100–1200 A Rated Secondary Current: 5 A / 1 A Rated Voltage: 0.66 kV Accuracy: 0.2S / 0.5S&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/83/Tu-68_Di-37Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LMZW-0.5(0.66) is a fully enclosed outdoor current transformer for low-voltage power systems, designed for energy metering, current measurement, and relay protection.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Current: 100–1200 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Rated Voltage: 0.66 kV</li>
<li>Accuracy: 0.2S / 0.5S / 0.2 / 0.5</li>
<li>Power Factor: 0.8 lagging</li>
<li>Power-Frequency Withstand: 3 kV</li>
<li>Frequency: 50/60 Hz</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LMZBJ9-10S 10kV Indoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-12.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-12.html</id>
        <media:content url="https://vaboelectric.com/media/posts/82/Tu-66_Di-35Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:42:38+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/82/Tu-66_Di-35Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LMZBJ9-10S is a fully enclosed epoxy-cast current transformer for 10kV indoor power systems, designed for current measurement, energy metering, and relay protection. Technical Parameters Rated Primary Current: 600/5–2500/5 A Rated Secondary Current: 5 A / 1 A Rated Voltage: ≤10 kV Accuracy Combinations: 0.2S/10P&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/82/Tu-66_Di-35Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LMZBJ9-10S is a fully enclosed epoxy-cast current transformer for 10kV indoor power systems, designed for current measurement, energy metering, and relay protection.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Current: 600/5–2500/5 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Rated Voltage: ≤10 kV</li>
<li>Accuracy Combinations: 0.2S/10P / 0.2/10P / 0.5/10P</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Installation: Indoor</li>
<li>Altitude: ≤1500 m</li>
<li>Relative Humidity: ≤90%</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LYM-0.5 Low-Voltage High-Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-11.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-11.html</id>
        <media:content url="https://vaboelectric.com/media/posts/81/Tu-60_Di-32Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:40:08+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/81/Tu-60_Di-32Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LYM-0.5 is an indoor low-voltage high-current transformer designed for busbar applications, providing accurate measurement, energy metering, and relay protection. Technical Parameters Rated Voltage: ≤0.66 kV Rated Secondary Current: 5 A / 1 A Accuracy: 0.2 / 0.5 / 0.2S / 0.5S Application: Measurement /&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/81/Tu-60_Di-32Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LYM-0.5 is an indoor low-voltage high-current transformer designed for busbar applications, providing accurate measurement, energy metering, and relay protection.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Voltage: ≤0.66 kV</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Accuracy: 0.2 / 0.5 / 0.2S / 0.5S</li>
<li>Application: Measurement / Metering / Protection</li>
<li>Installation: Indoor Busbar Type</li>
<li>Altitude: ≤2000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>VKH-0.66 Split-Core Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-10.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-10.html</id>
        <media:content url="https://vaboelectric.com/media/posts/80/Tu-58_Di-30Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:28:49+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/80/Tu-58_Di-30Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The VKH-0.66 is a split-core current transformer for low-voltage energy measurement and relay protection, offering large window sizes and high-current configurations. VKH-0.66-23 VKH-0.66-46 VKH-0.66-58 VKH-0.66-88 VKH-0.66-510 VKH-0.66-614 VKH-0.66-812 VKH-0.66-816 VKH-0.66-820 2000/5-8000/5 80×200
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/80/Tu-58_Di-30Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The VKH-0.66 is a split-core current transformer for low-voltage energy measurement and relay protection, offering large window sizes and high-current configurations.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Voltage: ≤0.66 kV</li>
<li>Current Range: 100/5–8000/5 A</li>
<li>Secondary Current: 5 A</li>
<li>Accuracy Class: 0.5</li>
<li>Rated Output: 2.5 / 5 / 10 VA</li>
<li>Window Sizes: 20×30 to 80×200 mm</li>
<li>Altitude: ≤1000 m</li>
</ul>
<div class="align-center" data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Outline Drawing and Installation Dimensions</span></strong></div>
<table style="border-collapse: collapse; width: 99.9694%;" border="1">
<tbody>
<tr>
<td class="align-center" style="width: 24.9924%;">
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Model</span></strong></div>
</td>
<td class="align-center" style="width: 24.9924%;">
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Current Ratio (A)</span></strong></div>
</td>
<td class="align-center" style="width: 24.9924%;">
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Window Dimension (mm)</span></strong></div>
</td>
<td class="align-center" style="width: 24.9924%;">
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Outline Dimension Drawing (mm)</span></strong></div>
</td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-23</p>
</td>
<td style="width: 24.9924%;">100/5-400/5</td>
<td style="width: 24.9924%;">20×30</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-49_Di-27Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" alt="" width="120" height="174" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-49_Di-27Ye_Dian-Liu-Hu-Gan-Qi-2-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-49_Di-27Ye_Dian-Liu-Hu-Gan-Qi-2-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-49_Di-27Ye_Dian-Liu-Hu-Gan-Qi-2-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-46</p>
</td>
<td style="width: 24.9924%;">300/5-1200/5</td>
<td style="width: 24.9924%;">40×60</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-50_Di-27Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="178" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-50_Di-27Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-50_Di-27Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-50_Di-27Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-58</p>
</td>
<td style="width: 24.9924%;">400/5-2000/5</td>
<td style="width: 24.9924%;">50×80</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-51_Di-27Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="177" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-51_Di-27Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-51_Di-27Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-51_Di-27Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-88</p>
</td>
<td style="width: 24.9924%;">400/5-2000/5</td>
<td style="width: 24.9924%;">80×80</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-52_Di-28Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="965" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-52_Di-28Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-52_Di-28Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-52_Di-28Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-510</p>
</td>
<td style="width: 24.9924%;">800/5-4000/5</td>
<td style="width: 24.9924%;">50×100</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-53_Di-28Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="187" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-53_Di-28Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-53_Di-28Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-53_Di-28Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-614</p>
</td>
<td style="width: 24.9924%;">1500/5-7500/5</td>
<td style="width: 24.9924%;">60×140</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-54_Di-28Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="188" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-54_Di-28Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-54_Di-28Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-54_Di-28Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-812</p>
</td>
<td style="width: 24.9924%;">1000/5-4000/5</td>
<td style="width: 24.9924%;">80×120</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-55_Di-29Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="185" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-55_Di-29Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-55_Di-29Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-55_Di-29Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-816</p>
</td>
<td style="width: 24.9924%;">1000/5-6000/5</td>
<td style="width: 24.9924%;">80×160</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-56_Di-29Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="190" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-56_Di-29Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-56_Di-29Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-56_Di-29Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
<tr>
<td style="width: 24.9924%;">
<p>VKH-0.66-820</p>
</td>
<td style="width: 24.9924%;">2000/5-8000/5</td>
<td style="width: 24.9924%;">80×200</td>
<td style="width: 24.9924%;"><figure class="post__image"><img loading="lazy"  src="https://vaboelectric.com/media/posts/80/Tu-57_Di-29Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="120" height="191" sizes="(max-width: 48em) 100vw, 100vw" srcset="https://vaboelectric.com/media/posts/80/responsive/Tu-57_Di-29Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,https://vaboelectric.com/media/posts/80/responsive/Tu-57_Di-29Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,https://vaboelectric.com/media/posts/80/responsive/Tu-57_Di-29Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure></td>
</tr>
</tbody>
</table>
            ]]>
        </content>
    </entry>
    <entry>
        <title>VCT-0.66 Split-Core Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-9.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-9.html</id>
        <media:content url="https://vaboelectric.com/media/posts/79/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:27:35+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/79/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The VCT-0.66 split-core current transformer allows quick installation and removal without disconnecting existing cables, making it suitable for retrofit projects and monitoring systems. Technical Parameters Primary Current Range: 5–1500 A Secondary Current: 5 A Accuracy Class: 0.5 Rated Output: 2.5 / 5 VA Power Factor:&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/79/Tu-47_Di-25Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The VCT-0.66 split-core current transformer allows quick installation and removal without disconnecting existing cables, making it suitable for retrofit projects and monitoring systems.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Primary Current Range: 5–1500 A</li>
<li>Secondary Current: 5 A</li>
<li>Accuracy Class: 0.5</li>
<li>Rated Output: 2.5 / 5 VA</li>
<li>Power Factor: 0.8 lagging</li>
<li>Window Size: Ø10–Ø50 mm</li>
<li>Altitude: ≤1000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LZZBJ9-11 11kV Indoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-8.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-8.html</id>
        <media:content url="https://vaboelectric.com/media/posts/78/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:19:22+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/78/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LZZBJ9-11 is a fully enclosed epoxy-cast current transformer for 11kV indoor systems, offering reliable metering and protection with high insulation performance and low partial discharge. Technical Parameters Rated Primary Current: 50–600 A Rated Secondary Current: 5 A / 1 A Accuracy: 0.2S / 0.5&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/78/Tu-15_Di-12Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LZZBJ9-11 is a fully enclosed epoxy-cast current transformer for 11kV indoor systems, offering reliable metering and protection with high insulation performance and low partial discharge.</p>
<h3> </h3>
<p data-start="533" data-end="557"><strong data-start="533" data-end="557">Technical Parameters</strong></p>
<ul>
<li>Rated Primary Current: 50–600 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Accuracy: 0.2S / 0.5 / 10P10</li>
<li>Rated Output: 10 / 15 VA</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Creepage Distance: 25 mm/kV</li>
<li>Installation: Indoor</li>
<li>Altitude: ≤3000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LZZW-11 11kV Outdoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-7.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-7.html</id>
        <media:content url="https://vaboelectric.com/media/posts/77/Tu-10_Di-10Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:19:20+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/77/Tu-10_Di-10Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LZZW-11 is an outdoor epoxy-cast current transformer for 11kV systems, designed for energy metering, current measurement, and relay protection. Technical Parameters Rated Primary Current: 50–600 A Rated Secondary Current: 5 A / 1 A Accuracy: 0.2S / 0.5 / 10P10 Rated Output: 10 /&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/77/Tu-10_Di-10Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LZZW-11 is an outdoor epoxy-cast current transformer for 11kV systems, designed for energy metering, current measurement, and relay protection.</p>
<p data-start="533" data-end="557"><strong data-start="533" data-end="557">Technical Parameters</strong></p>
<ul>
<li>Rated Primary Current: 50–600 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Accuracy: 0.2S / 0.5 / 10P10</li>
<li>Rated Output: 10 / 15 VA</li>
<li>Insulation Level: 12 / 42 / 75 kV</li>
<li>Installation: Outdoor</li>
<li>Altitude: ≤1000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LZZBJ9-33 35kV Indoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-6.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-6.html</id>
        <media:content url="https://vaboelectric.com/media/posts/76/Tu-8_Di-8Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:19:19+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/76/Tu-8_Di-8Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LZZBJ9-33 is a 35kV indoor epoxy-cast current transformer for current measurement, energy metering, monitoring, and relay protection in high-voltage power systems. Technical Parameters Rated Primary Current: 50–1200 A Rated Secondary Current: 5 A / 1 A Rated Voltage: 35 kV Accuracy Classes: 0.2S /&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/76/Tu-8_Di-8Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LZZBJ9-33 is a 35kV indoor epoxy-cast current transformer for current measurement, energy metering, monitoring, and relay protection in high-voltage power systems.</p>
<p data-start="533" data-end="557"><strong data-start="533" data-end="557">Technical Parameters</strong></p>
<ul>
<li>Rated Primary Current: 50–1200 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Rated Voltage: 35 kV</li>
<li>Accuracy Classes: 0.2S / 0.5 / 10P10</li>
<li>Rated Output: 15 / 20 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
<li>Installation: Indoor</li>
<li>Altitude: ≤2000 m</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>COL-24 24kV Outdoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-5.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-5.html</id>
        <media:content url="https://vaboelectric.com/media/posts/75/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:19:17+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/75/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The COL-24 is a 24kV oil-immersed current transformer for current and energy measurement in indoor and outdoor power systems. It offers 0.2S and 0.5 accuracy classes with reliable outdoor insulation. Main Parameters Rated Primary Current: 10 / 15 / 20 / 25 / 30 /&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/75/Tu-3_Di-4Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The COL-24 is a 24kV oil-immersed current transformer for current and energy measurement in indoor and outdoor power systems. It offers 0.2S and 0.5 accuracy classes with reliable outdoor insulation.</p>
<p data-start="1840" data-end="1859"><strong data-start="1840" data-end="1859">Main Parameters</strong></p>
<ul>
<li>Rated Primary Current: 10 / 15 / 20 / 25 / 30 / 40 A</li>
<li>Rated Secondary Current: 5 A</li>
<li>Rated Voltage: 24 kV</li>
<li>Accuracy Class: 0.2S / 0.5</li>
<li>Rated Output: 15 VA / 30 VA</li>
<li>Short-Time Thermal Current: 1–4 kA</li>
<li>Dynamic Current: 2.5–10 kA</li>
<li>Frequency: 50/60 Hz</li>
<li>Installation: Indoor / Outdoor</li>
<li>Standard: IEC 61869-2 / GB/T 20840.2</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LB-10 Oil-Immersed Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-4.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-4.html</id>
        <media:content url="https://vaboelectric.com/media/posts/74/Tu-1_Di-2Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:19:13+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/74/Tu-1_Di-2Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LB-10 is a 10kV oil-immersed current transformer designed for indoor and outdoor current and energy measurement in 50/60Hz power systems. It features 0.2S metering accuracy and reliable oil insulation. Specifications Rated Primary Current: 10–20 A Rated Secondary Current: 5 A Rated Voltage: 10 kV&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/74/Tu-1_Di-2Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p data-start="827" data-end="1198">The LB-10 is a 10kV oil-immersed current transformer designed for indoor and outdoor current and energy measurement in 50/60Hz power systems. It features 0.2S metering accuracy and reliable oil insulation.</p>
<p data-start="1200" data-end="1218"><strong data-start="1200" data-end="1218">Specifications</strong></p>
<ul data-start="1220" data-end="1466">
<li>Rated Primary Current: 10–20 A</li>
<li>Rated Secondary Current: 5 A</li>
<li>Rated Voltage: 10 kV</li>
<li>Accuracy Class: 0.2S</li>
<li>Rated Output: 15 VA</li>
<li>Rated Short-Time Thermal Current: 1 kA</li>
<li>Rated Dynamic Current: 2.5 kA</li>
<li>Frequency: 50/60 Hz</li>
<li>Installation: Indoor / Outdoor</li>
<li>Standard: IEC 61869-2 / GB/T 20840.2</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>AF Series Mini DIN-Rail Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-3.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-3.html</id>
        <media:content url="https://vaboelectric.com/media/posts/73/Tu-21_Di-14Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:16:28+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/73/Tu-21_Di-14Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The AF Series is a compact low-voltage current transformer for current measurement, energy metering, and relay protection, designed for DIN-rail or busbar mounting. Technical Parameters Models: AF-20 / AF-30 Rated Voltage: ≤0.72 kV Current Ratio: 15/5–300/5 A Accuracy Class: 1.0 Rated Secondary Current: 5 A&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/73/Tu-21_Di-14Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The AF Series is a compact low-voltage current transformer for current measurement, energy metering, and relay protection, designed for DIN-rail or busbar mounting.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Models: AF-20 / AF-30</li>
<li>Rated Voltage: ≤0.72 kV</li>
<li>Current Ratio: 15/5–300/5 A</li>
<li>Accuracy Class: 1.0</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Frequency: 50/60 Hz</li>
<li>Housing: UL94-V0 Flame-Retardant ABS</li>
<li>Installation: Indoor</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>BH-0.66 Low-Voltage Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033-2.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033-2.html</id>
        <media:content url="https://vaboelectric.com/media/posts/72/Tu-42_Di-21Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-10-14T15:13:44+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/72/Tu-42_Di-21Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The BH-0.66 is a molded-case low-voltage current transformer for current measurement and energy metering, with multiple window sizes and flexible busbar or base mounting. BH-0.66-20I BH-0.66-30I BH-0.66-40I BH-0.66-50I BH-0.66-60I BH-0.66-80I BH-0.66-100I BH-0.66-30II 30×30 BH-0.66-40II 40×30 BH-0.66-50II 50×30 BH-0.66-60II 60×30 BH-0.66-80II 80×30 BH-0.66-100II 100×30 BH-0.66-50III 50×50&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/72/Tu-42_Di-21Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The BH-0.66 is a molded-case low-voltage current transformer for current measurement and energy metering, with multiple window sizes and flexible busbar or base mounting.</p>
<h3>Technical Parameters</h3>
<ul>
<li>Rated Primary Current: 5–5000 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Accuracy: 0.2 / 0.5 / 1 / 3 / 0.2S / 0.5S</li>
<li>Rated Output: 2.5 / 5 / 10 / 20 / 30 VA</li>
<li>Maximum Equipment Voltage: 0.72 kV</li>
<li>Frequency: 50 Hz</li>
<li>Installation: Busbar / Base Mounting</li>
<li>Environment: Indoor</li>
</ul>
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-4">Outline drawing and installation dimensions </span></strong><strong style="font-size: inherit;"><span class="text-only" data-eleid="translation-4">(unit: mm)</span></strong></div>
<div data-lark-html-role="root">
<p class="align-center"><strong>BH-0.66-20I</strong></p>
<figure class="post__image align-center"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-25_Di-15Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="552" height="390" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-25_Di-15Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-25_Di-15Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-25_Di-15Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-30I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-26_Di-16Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="610" height="433" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-26_Di-16Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-26_Di-16Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-26_Di-16Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-40I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-27_Di-16Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="673" height="476" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-27_Di-16Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-27_Di-16Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-27_Di-16Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-50I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-28_Di-16Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="737" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-28_Di-16Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-28_Di-16Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-28_Di-16Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-60I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-29_Di-17Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="738" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-29_Di-17Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-29_Di-17Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-29_Di-17Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-80I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-30_Di-17Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" alt="" width="798" height="563" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-30_Di-17Ye_Dian-Liu-Hu-Gan-Qi-2-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-30_Di-17Ye_Dian-Liu-Hu-Gan-Qi-2-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-30_Di-17Ye_Dian-Liu-Hu-Gan-Qi-2-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-100I</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-31_Di-17Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="858" height="606" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-31_Di-17Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-31_Di-17Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-31_Di-17Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-30II   30×30</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="676" height="476" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-40II   40×30</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" alt="" width="676" height="476" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-2-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-2-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-33_Di-18Ye_Dian-Liu-Hu-Gan-Qi-2-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-50II   50×30</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-34_Di-18Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="738" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-34_Di-18Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-34_Di-18Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-34_Di-18Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-60II   60×30</strong></p>
<figure class="post__image align-center"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-35_Di-19Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="736" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-35_Di-19Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-35_Di-19Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-35_Di-19Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-80II   80×30</strong></p>
<figure class="post__image align-center"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-36_Di-19Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="798" height="563" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-36_Di-19Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-36_Di-19Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-36_Di-19Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-100II   100×30</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-37_Di-19Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="858" height="606" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-37_Di-19Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-37_Di-19Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-37_Di-19Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-50III   50×50</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-38_Di-20Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="737" height="520" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-38_Di-20Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-38_Di-20Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-38_Di-20Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-60III   60×50</strong></p>
<figure class="post__image"> <img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-39_Di-20Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="795" height="563" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-39_Di-20Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-39_Di-20Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-39_Di-20Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-80III   80×50</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-40_Di-20Ye_Dian-Liu-Hu-Gan-Qi-2.jpg" alt="" width="860" height="606" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-40_Di-20Ye_Dian-Liu-Hu-Gan-Qi-2-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-40_Di-20Ye_Dian-Liu-Hu-Gan-Qi-2-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-40_Di-20Ye_Dian-Liu-Hu-Gan-Qi-2-md.jpg 768w"></figure>
<p class="align-center"><strong>BH-0.66-100III   100×50</strong></p>
<figure class="post__image"><img loading="lazy"  src="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/Tu-41_Di-21Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" width="862" height="606" sizes="(max-width: 48em) 100vw, 100vw" srcset="file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-41_Di-21Ye_Dian-Liu-Hu-Gan-Qi-xs.jpg 300w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-41_Di-21Ye_Dian-Liu-Hu-Gan-Qi-sm.jpg 480w ,file:///C:/Users/gu/Documents/Publii/sites/gao-ji-zhu-ti-20261010/input/media/posts/71/responsive/Tu-41_Di-21Ye_Dian-Liu-Hu-Gan-Qi-md.jpg 768w"></figure>
<div data-lark-html-role="root"><strong><span class="text-only" data-eleid="translation-3">Note: Only diagrams for some common specifications and dimensions are provided above. Please contact us if you require other specifications.</span></strong></div>
</div>
            ]]>
        </content>
    </entry>
    <entry>
        <title>LZZW-33 35kV Outdoor Current Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/potato-washing-machine-px033.html"/>
        <id>https://vaboelectric.com/potato-washing-machine-px033.html</id>
        <media:content url="https://vaboelectric.com/media/posts/60/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Products"/>
            <category term="Current Transformers"/>

        <updated>2026-03-16T16:29:44+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/60/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" alt="" />
                    The LZZW-33 is a 35kV outdoor epoxy-cast current transformer for energy metering, current measurement, and relay protection, with up to three secondary windings. Technical Parameters Rated Primary Current: 50–600 A Rated Secondary Current: 5 A / 1 A Rated Voltage: 35 kV Accuracy Classes: 0.2S&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/60/Tu-6_Di-6Ye_Dian-Liu-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The LZZW-33 is a 35kV outdoor epoxy-cast current transformer for energy metering, current measurement, and relay protection, with up to three secondary windings.</p>
<p data-start="533" data-end="557"><strong data-start="533" data-end="557">Technical Parameters</strong></p>
<ul>
<li>Rated Primary Current: 50–600 A</li>
<li>Rated Secondary Current: 5 A / 1 A</li>
<li>Rated Voltage: 35 kV</li>
<li>Accuracy Classes: 0.2S / 0.5 / 10P10</li>
<li>Rated Output: 15 / 20 / 30 VA</li>
<li>Insulation Level: 40.5 / 95 / 185 kV</li>
<li>Installation: Outdoor</li>
<li>Frequency: 50/60 Hz</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JDJ2-33 33kV Outdoor Voltage Transformer</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/industrial-potato-washing-machine-cd6-series.html"/>
        <id>https://vaboelectric.com/industrial-potato-washing-machine-cd6-series.html</id>
        <media:content url="https://vaboelectric.com/media/posts/59/Tu-1_Di-1Ye_Dian-Ya-Hu-Gan-Qi.jpg" medium="image" />
            <category term="Voltage Transformers"/>
            <category term="Products"/>

        <updated>2026-03-16T15:09:04+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/59/Tu-1_Di-1Ye_Dian-Ya-Hu-Gan-Qi.jpg" alt="" />
                    The JDJ2-33 is a single-phase, oil-immersed outdoor voltage transformer designed for electrical measurement and relay protection in 33kV power systems. Specifications Rated Primary Voltage: 33 kV Rated Secondary Voltage: 0.11 kV Accuracy Class: 0.5 / 1 / 3 Rated Output: 150 / 250 / 500&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/59/Tu-1_Di-1Ye_Dian-Ya-Hu-Gan-Qi.jpg" class="type:primaryImage" alt="" /></p>
                <p>The JDJ2-33 is a single-phase, oil-immersed outdoor voltage transformer designed for electrical measurement and relay protection in 33kV power systems.</p>
<h3> </h3>
<p data-start="1200" data-end="1218"><strong data-start="1200" data-end="1218">Specifications</strong></p>
<ul data-start="1220" data-end="1466">
<li>Rated Primary Voltage: 33 kV</li>
<li>Rated Secondary Voltage: 0.11 kV</li>
<li>Accuracy Class: 0.5 / 1 / 3</li>
<li>Rated Output: 150 / 250 / 500 VA</li>
<li>Maximum Output: 1000 VA</li>
<li>Insulation Level: 40.5 / 95 / 200 kV</li>
<li>Frequency: 50 Hz</li>
<li>Installation: Outdoor</li>
<li>Ambient Temperature: -25°C to +40°C</li>
<li>Altitude: ≤2000 m</li>
<li>Wind Speed: &lt;34 m/s</li>
<li>Standard: IEC 61869-3 / GB/T 20840.3</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>35kV Three-Phase Outdoor Metering Unit</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/brush-type-potato-cleaning-machine-268.html"/>
        <id>https://vaboelectric.com/brush-type-potato-cleaning-machine-268.html</id>
        <media:content url="https://vaboelectric.com/media/posts/58/Tu-2_Di-1Ye_35kV-Metering-Unit-Manual-English-Edition.jpg" medium="image" />
            <category term="Products"/>
            <category term="Metering Units"/>

        <updated>2026-03-16T15:08:48+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/58/Tu-2_Di-1Ye_35kV-Metering-Unit-Manual-English-Edition.jpg" alt="" />
                    The 35kV three-phase outdoor metering unit integrates current transformers and voltage transformers in one oil-immersed enclosure for accurate active and reactive energy metering on high-voltage power systems. Main Parameters Product Type: C.T. / V.T. Metering Unit Rated Primary Voltage: 35 kV Rated Frequency: 50 Hz&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/58/Tu-2_Di-1Ye_35kV-Metering-Unit-Manual-English-Edition.jpg" class="type:primaryImage" alt="" /></p>
                <p>The 35kV three-phase outdoor metering unit integrates current transformers and voltage transformers in one oil-immersed enclosure for accurate active and reactive energy metering on high-voltage power systems.</p>
<p data-start="1840" data-end="1859"><strong data-start="1840" data-end="1859">Main Parameters</strong></p>
<ul>
<li>Product Type: C.T. / V.T. Metering Unit</li>
<li>Rated Primary Voltage: 35 kV</li>
<li>Rated Frequency: 50 Hz</li>
<li>Rated Voltage Ratio: 33000 / 110 V</li>
<li>Rated Primary Current: 2.5–100 A</li>
<li>Rated Secondary Current: 5 A or 1 A</li>
<li>Accuracy Class: 0.2 / 0.5 / 0.2S / 0.5S</li>
<li>Voltage Core Rated Output: 3 × 50 VA</li>
<li>Current Core Rated Output: 3 × 50 VA</li>
<li>Connection: Y/Y0</li>
<li>Structure: Three-Phase, Three-Element</li>
<li>Insulation Type: Oil-Immersed</li>
<li>Installation: Outdoor</li>
</ul>
            ]]>
        </content>
    </entry>
    <entry>
        <title>JLSZ□-10 10kV Outdoor Combined Metering Unit</title>
        <author>
            <name>Vabo</name>
        </author>
        <link href="https://vaboelectric.com/commercial-potato-washing-equipment-117.html"/>
        <id>https://vaboelectric.com/commercial-potato-washing-equipment-117.html</id>
        <media:content url="https://vaboelectric.com/media/posts/56/Tu-2_Di-1Ye_JLSZ-10-Product-Manual-English-Edition.jpg" medium="image" />
            <category term="Products"/>
            <category term="Combined Instrument Transformers"/>

        <updated>2026-03-16T13:56:45+08:00</updated>
            <summary type="html">
                <![CDATA[
                        <img src="https://vaboelectric.com/media/posts/56/Tu-2_Di-1Ye_JLSZ-10-Product-Manual-English-Edition.jpg" alt="" />
                    The JLSZ□-10 is a three-phase outdoor combined metering unit integrating current and voltage transformers for direct active and reactive energy metering in 10kV power systems. Technical Details Technical Parameters Parameter Value Model JLSZ□-10 Rated Primary Voltage 10 kV Rated Frequency 50 Hz Rated Voltage Ratio&hellip;
                ]]>
            </summary>
        <content type="html">
            <![CDATA[
                    <p><img src="https://vaboelectric.com/media/posts/56/Tu-2_Di-1Ye_JLSZ-10-Product-Manual-English-Edition.jpg" class="type:primaryImage" alt="" /></p>
                <p data-start="2148" data-end="2487">The JLSZ□-10 is a three-phase outdoor combined metering unit integrating current and voltage transformers for direct active and reactive energy metering in 10kV power systems.</p>
<p data-start="2489" data-end="2510"><strong data-start="2489" data-end="2510">Technical Details</strong></p>
<ul>
<li>10kV System </li>
<li>CT &amp; VT Integrated</li>
<li>0.2S / 0.5S Accuracy </li>
<li>Outdoor Epoxy Cast </li>
<li>V/V &amp; Y/Y Configurations </li>
<li>Active &amp; Reactive Metering</li>
</ul>
<p> </p>
<h2 class="align-center"><span style="font-size: 14pt; color: #000000;">Technical Parameters</span></h2>
<div>
<div>
<div>
<table style="width: 100.015%; height: 501.5px;">
<thead>
<tr style="height: 50.15px;">
<th style="width: 45.2314%; height: 50.15px;">Parameter</th>
<th style="width: 54.8281%; height: 50.15px;">Value</th>
</tr>
</thead>
<tbody>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Model</strong></td>
<td style="width: 54.8281%; height: 50.15px;">JLSZ□-10</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Rated Primary Voltage</strong></td>
<td style="width: 54.8281%; height: 50.15px;">10 kV</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Rated Frequency</strong></td>
<td style="width: 54.8281%; height: 50.15px;">50 Hz</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Rated Voltage Ratio</strong></td>
<td style="width: 54.8281%; height: 50.15px;">10000 / 100 V</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Rated Primary Current</strong></td>
<td style="width: 54.8281%; height: 50.15px;">2.5–100 A, stepped</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Rated Secondary Current</strong></td>
<td style="width: 54.8281%; height: 50.15px;">5 A or 1 A</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Accuracy Class</strong></td>
<td style="width: 54.8281%; height: 50.15px;">0.2 / 0.5 / 0.2S / 0.5S</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Dual-Ratio CT Taps</strong></td>
<td style="width: 54.8281%; height: 50.15px;">S1-S2 low ratio / S1-S3 high ratio</td>
</tr>
<tr style="height: 50.15px;">
<td style="width: 45.2314%; height: 50.15px;"><strong>Installation</strong></td>
<td style="width: 54.8281%; height: 50.15px;">Outdoor</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
            ]]>
        </content>
    </entry>
</feed>